简要描述:Equipment introduction softening device: the control valve uses an automatic control valve. The automatic controller is based on the world-renowned FLECK company's water softening technology. It fully automatically controls every step of the softener operation and regeneration, using time flow or sensors to initiate regeneration. The fully automatic water softener controls all operating procedures, allowing the device to supply water continuously (or intermittently). The regeneration device is automatically started by the controller, and the size can be set according to the desired regeneration program. Because
产品型号
厂商性质
更新时间
浏览次数
产品分类
Equipment Introduction
softening device, the control valve uses an automatic control valve. The automatic controller is based on the world-renowned FLECK company water softener technology. It fully automatically controls every step of the water softener operation and regeneration, starting regeneration via time flow or sensors.
The fully automatic water softener controls all operating programs, allowing the equipment to supply water continuously (or intermittently). The regeneration device is automatically started by the controller, and the size can be set according to the desired regeneration program. Thanks to mature technology and easy operation of the fully automatic water softening equipment control system, the controller uses a lead-free brass valve body, fully meeting the requirements of food hygiene and hygiene, and is coated with polytetrafluoroethylene (Teflon), the piston reduces resistance, extends service life, and ensures reliable operation.
automatic water softeners can be used in hotels, food industries, petrochemicals, laundry printing and dyeing, medical and health sectors, and other sectors. This product features a high degree of automation, large exchange capacity, compact structure, low energy consumption, labor savings, and no need for daily maintenance.
device parameters
1. Inlet pressure: 0.3Mpa—0.5Mpa;
2. Operating temperature: 2°C–50°C;
3. Inlet hardness ≤6mmoI/L;
4. Outlet hardness: ≤0.03 mmoI/L;
5. Power supply: 220V/50Hz;
6. Layout type: single valve single tank / double valve double tank type;
7. Regeneration method: downstream regeneration, one in use, one standby;
8. Operating Program: Automatic program control;
9. Resin used: 001×7 strongly acidic cation exchange resin;