简要描述:Performance and Features: ◆ Nominal diameter: DN40... DN250; ◆ Differential pressure range: 300-1000mbar (DN40~50) or 400-1600mbar (DN65~250); ◆ Working pressure differential: △PV≤3500mbar; ◆ High-quality stepless pressure regulation structure; ◆ Uses advanced diaphragm technology with zero theoretical error and can withstand a pressure difference of 0.8MPa; ◆ Supports internal autonomous regulation within the controlled system, eliminating the impact of external grid pressure difference fluctuations on the controlled system; ◆
产品型号
厂商性质
更新时间
浏览次数
产品分类
Performance and Features:
◆ nominal diameter: DN40... DN250;
Pressure difference range: 300-1000mbar (DN40~50) or 400-1600mbar (DN65~250);
◆ Working pressure difference: △ PV ≤ 3500mbar;
◆ High quality stepless voltage regulation structure;
Adopting excellent technology membrane, with zero theoretical error, and able to withstand a pressure difference of 0.8 MPa;
◆ Support internal autonomous adjustment of the controlled system to eliminate the impact of external network pressure fluctuations on the controlled system;
◆ Reliable opening memory function;
EPDM sealing, reliable sealing performance;
◆ Compliant with PED manufacturing license.
Application and Working Principle:
Dynamic differential pressure balancing valve is an automatic constant pressure balancing valve used in constant air conditioning or heating systems to control the pressure difference between control valves, end devices, or water supply in the pipeline network, avoiding dynamic interference from changes in pipeline pressure and achieving dynamic hydraulic balance.
Its working principle is that when the pressure difference of the system pipeline network increases, the dynamic pressure balance valve relies on its own high and low pressure chamber pressure changes to act on both sides of the diaphragm to re balance the force, while driving the valve stem to move and reduce the valve opening, absorbing the increased pressure difference of the resources and ensuring a constant pressure difference on the controlled side.
The combination of dynamic pressure balance valve and static balance valve can solve the hydraulic imbalance of variable flow system. When the pressure or flow changes in the system pipeline network, this configuration can effectively adjust the pressure difference of the inlet and outlet pipelines to be constant.
Model Description:
Example: DPBV100-0FP01
1. The abbreviation for "DPBV" differential pressure balancing valve;
2. "100" caliber DN100;
3. "-" delimiter;
4. "0F" standard configuration, flange connection-F, threaded connection-S;
5. "P01" pressure rating, abbreviated as PN16.
If the customer has special requirements, they can be noted at the end.
Parameter table:
Model/PN16 | Model/PN25 | Pipe diameter(in.) | DN(mm) | Kvs | Temperature(℃) |
DPBV040-0FP01 | DPBV 040-0FP02 | 1-1/2" | 40 | 15 | -10~100℃ |
DPBV 050-0FP01 | DPBV 050-0FP02 | 2" | 50 | 34 | |
DPBV 065-0FP01 | DPBV 065-0FP02 | 2-1/2" | 65 | 52 | |
DPBV 080-0FP01 | DPBV 080-0FP02 | 3" | 80 | 75 | |
DPBV 100-0FP01 | DPBV 100-0FP02 | 4" | 100 | 110 | |
DPBV 125-0FP01 | DPBV 125-0FP02 | 5" | 125 | 160 | |
DPBV 150-0FP01 | DPBV 150-0FP02 | 6" | 150 | 280 | |
DPBV 200-0FP01 | DPBV 200-0FP02 | 8" | 200 | 320 | |
DPBV 250-0FP01 | DPBV 250-0FP02 | 10" | 250 | 400 |
Note:
1. Flow deviation ≤ 5%;
2. We can provide two different flange connection standards, PN16 and PN25.
下一篇
没有了!